{"id":4933,"date":"2025-07-09T04:31:58","date_gmt":"2025-07-09T04:31:58","guid":{"rendered":"https:\/\/mestekinstruments.com\/?p=4933"},"modified":"2025-07-09T04:32:00","modified_gmt":"2025-07-09T04:32:00","slug":"how-to-test-inrush-current-using-a-clamp-meter","status":"publish","type":"post","link":"https:\/\/mestekinstruments.com\/fr\/how-to-test-inrush-current-using-a-clamp-meter\/","title":{"rendered":"How to Test Inrush Current Using a Clamp Meter?"},"content":{"rendered":"<p>Measuring inrush current\u2014also known as surge current\u2014is critical when diagnosing equipment that experiences sudden bursts of electricity during startup. Motors, compressors, HVAC systems, and even vehicle engines all produce inrush currents that, if left unmeasured, can lead to overlooked failures or incorrectly sized protective components.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>What Is Inrush Current?<\/strong><\/h2>\n\n\n\n<p>Inrush current is the initial surge of current drawn when electrical devices are powered on. It can be 5\u201310 times higher than the steady-state current, lasting only milliseconds\u2014but those milliseconds can damage circuits, trip breakers, or mislead diagnostics if not properly monitored.<\/p>\n\n\n\n<p>Example: An air compressor may normally draw 8A, but on startup, it could briefly pull 60A or more.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Use a Clamp Meter for Inrush Current?<\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"790\" height=\"824\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\" alt=\"\" class=\"wp-image-4942\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg 790w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71-288x300.jpg 288w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71-768x801.jpg 768w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71-600x626.jpg 600w\" sizes=\"(max-width: 790px) 100vw, 790px\" \/><\/figure>\n\n\n\n<p>Clamp meters with inrush current functionality are non-invasive tools that let you:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measure high current safely without disconnecting wires<\/li>\n\n\n\n<li>Capture peak startup current within milliseconds<\/li>\n\n\n\n<li>Analyze electrical performance under load<\/li>\n\n\n\n<li>Troubleshoot nuisance tripping or underperforming devices<\/li>\n<\/ul>\n\n\n\n<p>A regular clamp meter may only show average RMS current. For inrush, you need a meter that specifically features \u201cINRUSH\u201d mode.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How to Measure Inrush Current?<\/strong><\/h2>\n\n\n\n<p>1. Choose a Clamp Meter with Inrush Mode<\/p>\n\n\n\n<p>Make sure your meter explicitly supports inrush current measurement.<\/p>\n\n\n\n<p>2. Set the Meter to Inrush Mode<\/p>\n\n\n\n<p>Most models have a dedicated button or mode selector for INRUSH.<\/p>\n\n\n\n<p>3. Clamp Around One Conductor Only<\/p>\n\n\n\n<p>Never clamp around both hot and neutral wires together\u2014current will cancel out.<\/p>\n\n\n\n<p>4. Start the Device<\/p>\n\n\n\n<p>Trigger the startup while the meter is active in inrush mode.<\/p>\n\n\n\n<p>5. Read the Peak Current<\/p>\n\n\n\n<p>The clamp meter will capture and hold the maximum current drawn during the first few cycles.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Recommended Clamp Meters with Inrush Current Capability<\/strong><\/h2>\n\n\n\n<p>Here are three professional-grade clamp meters you can rely on for accurate inrush current testing:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong><a href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-376-fc\">Fluke 376 FC Clamp Meter<\/a><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67-1024x683.png\" alt=\"\" class=\"wp-image-4936\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67-1024x683.png 1024w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67-300x200.png 300w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67-768x512.png 768w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67-600x400.png 600w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/67.png 1500w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Inrush Current Measurement: Yes<\/p>\n\n\n\n<p>True RMS + iFlex Flex Probe: For measuring around awkward wires<\/p>\n\n\n\n<p>Max Current: Up to 2500A (with iFlex)<\/p>\n\n\n\n<p>Other Features: Logging, wireless connectivity via Fluke Connect<\/p>\n\n\n\n<p>Why Choose: Trusted by professionals for heavy-duty industrial measurements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong><a href=\"https:\/\/mestekinstruments.com\/fr\/product\/clamp-meters\/cm86b\/\">MESTEK CM86B Clamp Meter<\/a><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17.png\" alt=\"\" class=\"wp-image-2136\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17.png 800w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17-300x300.png 300w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17-150x150.png 150w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17-768x768.png 768w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17-600x600.png 600w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2024\/12\/1-17-100x100.png 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">clamp meter series for CM86B<\/figcaption><\/figure>\n\n\n\n<p>Inrush Current Measurement: Yes<\/p>\n\n\n\n<p>True RMS: For accurate AC measurements<\/p>\n\n\n\n<p>Max Current: Up to 1000A<\/p>\n\n\n\n<p>Other Features: NCV, temperature, capacitance, diode test<\/p>\n\n\n\n<p>Why Choose: Feature-rich clamp meter ideal for electricians and HVAC professionals who need to perform surge diagnostics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong><a href=\"https:\/\/www.kleintools.com\/catalog\/clamp-meters\/digital-clamp-meter-ac-auto-range-trms-low-impedance-loz-auto\">Klein Tools CL800<\/a><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68.png\" alt=\"\" class=\"wp-image-4938\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68.png 1000w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68-300x300.png 300w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68-150x150.png 150w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68-768x768.png 768w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68-600x600.png 600w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/68-100x100.png 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p>Inrush Current Measurement: Yes<\/p>\n\n\n\n<p>True RMS: Accurate for non-linear loads<\/p>\n\n\n\n<p>Max Current: Up to 1000A<\/p>\n\n\n\n<p>Other Features: LoZ mode for ghost voltage elimination, temperature measurement<\/p>\n\n\n\n<p>Why Choose: Affordable, rugged, and suitable for general electrical and HVAC work.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong><a href=\"https:\/\/meters.uni-trend.com\/product\/ut210-series\/\">UNI-T UT210E Pro Clamp Meter<\/a><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"498\" height=\"500\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/69.png\" alt=\"\" class=\"wp-image-4939\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/69.png 498w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/69-300x300.png 300w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/69-150x150.png 150w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/69-100x100.png 100w\" sizes=\"(max-width: 498px) 100vw, 498px\" \/><\/figure>\n\n\n\n<p>Inrush Current Measurement: Yes (short burst current supported)<\/p>\n\n\n\n<p>True RMS: Yes<\/p>\n\n\n\n<p>Max Current: Up to 200A<\/p>\n\n\n\n<p>Other Features: Compact size, auto range, voltage\/resistance\/capacitance\/continuity test<\/p>\n\n\n\n<p>Why Choose: A highly portable clamp meter, ideal for low-current inrush testing in electronics, control panels, and automotive wiring diagnostics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong><a href=\"https:\/\/www.flir.eu\/products\/ma445\/\">Extech MA445 Clamp Meter<\/a><\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"625\" src=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/70.png\" alt=\"\" class=\"wp-image-4940\" style=\"width:500px\" srcset=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/70.png 600w, https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/70-288x300.png 288w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p>Inrush Current Measurement: Yes<\/p>\n\n\n\n<p>True RMS: Yes<\/p>\n\n\n\n<p>Max Current: Up to 600A AC\/DC<\/p>\n\n\n\n<p>Other Features: Dual display, non-contact voltage, temperature probe, frequency and duty cycle<\/p>\n\n\n\n<p>Why Choose: A mid-range clamp meter with solid inrush performance and a wide feature set, well-suited for HVAC and industrial techs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Pro Tips<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use clamp meters with fast sample rates (\u22651kHz) for better inrush capture.<\/li>\n\n\n\n<li>Always verify safety ratings (CAT III or IV) depending on your working environment.<\/li>\n\n\n\n<li>For automotive applications, ensure the clamp meter handles 600A+ inrush, especially for diesel engines.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusion<\/strong><\/h2>\n\n\n\n<p>Inrush current testing is essential for uncovering startup issues in motors, HVAC compressors, and even automotive systems. By using a clamp meter equipped with INRUSH mode\u2014like the <a href=\"https:\/\/mestekinstruments.com\/fr\/\">MESTEK CM86B<\/a>\u2014you\u2019ll get safe, accurate, and actionable readings within seconds.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Measuring inrush current\u2014also known as surge current\u2014is critical when diagnosing equipment that experiences sudden bursts of electricity during startup. Motors, compressors, HVAC systems, and even vehicle engines all produce inrush currents that, if left unmeasured, can lead to overlooked failures or incorrectly sized protective components. What Is Inrush Current? Inrush current is the initial surge of current drawn when electrical devices are powered on. It can be 5\u201310 times higher than the steady-state current, lasting only milliseconds\u2014but those milliseconds can damage circuits, trip breakers, or mislead diagnostics if not properly monitored. Example: An air compressor may normally draw 8A, but [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4942,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4933","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to Test Inrush Current Using a Clamp Meter?<\/title>\n<meta name=\"description\" content=\"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mestekinstruments.com\/fr\/how-to-test-inrush-current-using-a-clamp-meter\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Test Inrush Current Using a Clamp Meter?\" \/>\n<meta property=\"og:description\" content=\"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mestekinstruments.com\/fr\/how-to-test-inrush-current-using-a-clamp-meter\/\" \/>\n<meta property=\"og:site_name\" content=\"MESTEK\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-09T04:31:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-09T04:32:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"790\" \/>\n\t<meta property=\"og:image:height\" content=\"824\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"MESTEK\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"MESTEK\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/\"},\"author\":{\"name\":\"MESTEK\",\"@id\":\"https:\/\/mestekinstruments.com\/#\/schema\/person\/7c95c9fb2ea2fd8a49ae2df686b899cc\"},\"headline\":\"How to Test Inrush Current Using a Clamp Meter?\",\"datePublished\":\"2025-07-09T04:31:58+00:00\",\"dateModified\":\"2025-07-09T04:32:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/\"},\"wordCount\":616,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/mestekinstruments.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/\",\"url\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/\",\"name\":\"How to Test Inrush Current Using a Clamp Meter?\",\"isPartOf\":{\"@id\":\"https:\/\/mestekinstruments.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\",\"datePublished\":\"2025-07-09T04:31:58+00:00\",\"dateModified\":\"2025-07-09T04:32:00+00:00\",\"description\":\"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.\",\"breadcrumb\":{\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage\",\"url\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\",\"contentUrl\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg\",\"width\":790,\"height\":824,\"caption\":\"Technician testing inrush current on an electrical panel using a clamp meter\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/mestekinstruments.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Test Inrush Current Using a Clamp Meter?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/mestekinstruments.com\/#website\",\"url\":\"https:\/\/mestekinstruments.com\/\",\"name\":\"MESTEK\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/mestekinstruments.com\/#organization\"},\"alternateName\":\"MESTEK\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/mestekinstruments.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/mestekinstruments.com\/#organization\",\"name\":\"MESTEK\",\"url\":\"https:\/\/mestekinstruments.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/mestekinstruments.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/02\/mestek-logo-\u65b0.png\",\"contentUrl\":\"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/02\/mestek-logo-\u65b0.png\",\"width\":180,\"height\":60,\"caption\":\"MESTEK\"},\"image\":{\"@id\":\"https:\/\/mestekinstruments.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/mestekinstruments.com\/#\/schema\/person\/7c95c9fb2ea2fd8a49ae2df686b899cc\",\"name\":\"MESTEK\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/mestekinstruments.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/mestekinstruments.com\/wp-content\/litespeed\/avatar\/607bb295a8d94a77016db07ec31f580c.jpg?ver=1787432429\",\"contentUrl\":\"https:\/\/mestekinstruments.com\/wp-content\/litespeed\/avatar\/607bb295a8d94a77016db07ec31f580c.jpg?ver=1787432429\",\"caption\":\"MESTEK\"},\"sameAs\":[\"http:\/\/mestekinstruments.com\"],\"url\":\"https:\/\/mestekinstruments.com\/fr\/author\/tonyakclarkj73gmail-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Test Inrush Current Using a Clamp Meter?","description":"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mestekinstruments.com\/fr\/how-to-test-inrush-current-using-a-clamp-meter\/","og_locale":"fr_FR","og_type":"article","og_title":"How to Test Inrush Current Using a Clamp Meter?","og_description":"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.","og_url":"https:\/\/mestekinstruments.com\/fr\/how-to-test-inrush-current-using-a-clamp-meter\/","og_site_name":"MESTEK","article_published_time":"2025-07-09T04:31:58+00:00","article_modified_time":"2025-07-09T04:32:00+00:00","og_image":[{"width":790,"height":824,"url":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg","type":"image\/jpeg"}],"author":"MESTEK","twitter_card":"summary_large_image","twitter_misc":{"Written by":"MESTEK","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#article","isPartOf":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/"},"author":{"name":"MESTEK","@id":"https:\/\/mestekinstruments.com\/#\/schema\/person\/7c95c9fb2ea2fd8a49ae2df686b899cc"},"headline":"How to Test Inrush Current Using a Clamp Meter?","datePublished":"2025-07-09T04:31:58+00:00","dateModified":"2025-07-09T04:32:00+00:00","mainEntityOfPage":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/"},"wordCount":616,"commentCount":0,"publisher":{"@id":"https:\/\/mestekinstruments.com\/#organization"},"image":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg","articleSection":["Uncategorized"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/","url":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/","name":"How to Test Inrush Current Using a Clamp Meter?","isPartOf":{"@id":"https:\/\/mestekinstruments.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage"},"image":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg","datePublished":"2025-07-09T04:31:58+00:00","dateModified":"2025-07-09T04:32:00+00:00","description":"Learn how to test inrush current using a clamp meter. Follow step-by-step tips and explore 5 clamp meters for accurate surge diagnostics.","breadcrumb":{"@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#primaryimage","url":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg","contentUrl":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/07\/71.jpg","width":790,"height":824,"caption":"Technician testing inrush current on an electrical panel using a clamp meter"},{"@type":"BreadcrumbList","@id":"https:\/\/mestekinstruments.com\/how-to-test-inrush-current-using-a-clamp-meter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/mestekinstruments.com\/"},{"@type":"ListItem","position":2,"name":"How to Test Inrush Current Using a Clamp Meter?"}]},{"@type":"WebSite","@id":"https:\/\/mestekinstruments.com\/#website","url":"https:\/\/mestekinstruments.com\/","name":"MESTEK","description":"","publisher":{"@id":"https:\/\/mestekinstruments.com\/#organization"},"alternateName":"MESTEK","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mestekinstruments.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/mestekinstruments.com\/#organization","name":"MESTEK","url":"https:\/\/mestekinstruments.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/mestekinstruments.com\/#\/schema\/logo\/image\/","url":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/02\/mestek-logo-\u65b0.png","contentUrl":"https:\/\/mestekinstruments.com\/wp-content\/uploads\/2025\/02\/mestek-logo-\u65b0.png","width":180,"height":60,"caption":"MESTEK"},"image":{"@id":"https:\/\/mestekinstruments.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/mestekinstruments.com\/#\/schema\/person\/7c95c9fb2ea2fd8a49ae2df686b899cc","name":"MESTEK","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/mestekinstruments.com\/#\/schema\/person\/image\/","url":"https:\/\/mestekinstruments.com\/wp-content\/litespeed\/avatar\/607bb295a8d94a77016db07ec31f580c.jpg?ver=1787432429","contentUrl":"https:\/\/mestekinstruments.com\/wp-content\/litespeed\/avatar\/607bb295a8d94a77016db07ec31f580c.jpg?ver=1787432429","caption":"MESTEK"},"sameAs":["http:\/\/mestekinstruments.com"],"url":"https:\/\/mestekinstruments.com\/fr\/author\/tonyakclarkj73gmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/posts\/4933","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/comments?post=4933"}],"version-history":[{"count":0,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/posts\/4933\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/media\/4942"}],"wp:attachment":[{"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/media?parent=4933"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/categories?post=4933"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mestekinstruments.com\/fr\/wp-json\/wp\/v2\/tags?post=4933"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}